Added timings
This commit is contained in:
parent
695e283246
commit
6ab9bed2b4
18
README.md
18
README.md
@ -103,4 +103,20 @@ For ease of adaption, connection, and prototyping I've decided to use Cat 5 ethe
|
||||
1 | auger_off | 1400
|
||||
2 | pause | 5000
|
||||
3 | igniter_start | 420000
|
||||
4 | blower_stop | 600000
|
||||
4 | blower_stop | 600000
|
||||
|
||||
# Startup Procedure
|
||||
1. Manually toggle the "I" Igniter switch ON
|
||||
2. Wait 60 seconds
|
||||
3. Manually toggle the "E" Exhaust switch ON
|
||||
4. Using the Hestia Web Portal, set Feed Rate to 2
|
||||
5. Enable the Auger
|
||||
6. Wait up to three minutes for pellets to ignite
|
||||
7. Manually toggle the "I" Ingniter switch OFF
|
||||
8. Monitor fire and adjust feed rates as necessary
|
||||
|
||||
# Timings
|
||||
* 60-90 seconds igniter preheat
|
||||
* 120-180 seconds for pellet ignition
|
||||
* 4 minutes from ignition to PoF Close
|
||||
* 7:30 minutes total
|