From 6ab9bed2b41a9516812002131dcfa63c3c366fe4 Mon Sep 17 00:00:00 2001 From: Skylar Grant Date: Mon, 13 Nov 2023 17:35:25 -0500 Subject: [PATCH] Added timings --- README.md | 18 +++++++++++++++++- 1 file changed, 17 insertions(+), 1 deletion(-) diff --git a/README.md b/README.md index 7acabdc..1888709 100644 --- a/README.md +++ b/README.md @@ -103,4 +103,20 @@ For ease of adaption, connection, and prototyping I've decided to use Cat 5 ethe 1 | auger_off | 1400 2 | pause | 5000 3 | igniter_start | 420000 -4 | blower_stop | 600000 \ No newline at end of file +4 | blower_stop | 600000 + +# Startup Procedure +1. Manually toggle the "I" Igniter switch ON +2. Wait 60 seconds +3. Manually toggle the "E" Exhaust switch ON +4. Using the Hestia Web Portal, set Feed Rate to 2 +5. Enable the Auger +6. Wait up to three minutes for pellets to ignite +7. Manually toggle the "I" Ingniter switch OFF +8. Monitor fire and adjust feed rates as necessary + +# Timings +* 60-90 seconds igniter preheat +* 120-180 seconds for pellet ignition +* 4 minutes from ignition to PoF Close +* 7:30 minutes total \ No newline at end of file