Added timings

This commit is contained in:
Skylar Grant 2023-11-13 17:35:25 -05:00
parent 695e283246
commit 6ab9bed2b4

View File

@ -104,3 +104,19 @@ For ease of adaption, connection, and prototyping I've decided to use Cat 5 ethe
2 | pause | 5000
3 | igniter_start | 420000
4 | blower_stop | 600000
# Startup Procedure
1. Manually toggle the "I" Igniter switch ON
2. Wait 60 seconds
3. Manually toggle the "E" Exhaust switch ON
4. Using the Hestia Web Portal, set Feed Rate to 2
5. Enable the Auger
6. Wait up to three minutes for pellets to ignite
7. Manually toggle the "I" Ingniter switch OFF
8. Monitor fire and adjust feed rates as necessary
# Timings
* 60-90 seconds igniter preheat
* 120-180 seconds for pellet ignition
* 4 minutes from ignition to PoF Close
* 7:30 minutes total