2022-12-22 02:07:46 +00:00
|
|
|
[0] I: Not running on a Raspberry Pi.
|
|
|
|
== Lennox Winslow PS40
|
|
|
|
== Pellet Stove Control Panel
|
|
|
|
== Author: Skylar Grant
|
|
|
|
== Version: v0.2.1
|
|
|
|
==
|
2023-01-03 22:01:23 +00:00
|
|
|
== Startup Time: 2023-01-03T15:56:33.395Z
|
2022-12-22 02:07:46 +00:00
|
|
|
==
|
|
|
|
== Environment variables:
|
|
|
|
== == ONTIME=500
|
|
|
|
== == OFFTIME=1500
|
|
|
|
== == PAUSETIME=3000
|
|
|
|
== == DEBUG=true
|
|
|
|
== == ONPI=false
|
2023-01-03 22:01:23 +00:00
|
|
|
[0.009] I: == GPIO Not Available
|
|
|
|
[0.01] I: Pausing for 3000ms
|
|
|
|
[3.013] I: Pausing for 3000ms
|
2022-12-22 02:07:46 +00:00
|
|
|
[6.015] I: Pausing for 3000ms
|
2023-01-03 22:01:23 +00:00
|
|
|
[9.017] I: Pausing for 3000ms
|
|
|
|
[12.019] I: Pausing for 3000ms
|
|
|
|
[15.022] I: Pausing for 3000ms
|
|
|
|
[18.025] I: Pausing for 3000ms
|
|
|
|
[21.027] I: Pausing for 3000ms
|
|
|
|
[24.028] I: Pausing for 3000ms
|
|
|
|
[27.03] I: Pausing for 3000ms
|
|
|
|
[30.032] I: Pausing for 3000ms
|
|
|
|
[33.034] I: Pausing for 3000ms
|
|
|
|
[36.037] I: Pausing for 3000ms
|
|
|
|
[39.039] I: Pausing for 3000ms
|
|
|
|
[42.041] I: Pausing for 3000ms
|
|
|
|
[45.042] I: Pausing for 3000ms
|
|
|
|
[48.044] I: Pausing for 3000ms
|
|
|
|
[51.046] I: Pausing for 3000ms
|
|
|
|
[52.551] I: Blower turned on.
|
|
|
|
[52.552] I: Igniter turned on.
|
|
|
|
[52.552] I: Auger enabled.
|
|
|
|
[54.047] I: The igniter is on. Started: 10:57:25. Stopping: 10:57:30.
|
|
|
|
[54.048] I: Auger disabled.
|
|
|
|
Shutdown has been initiated.
|
|
|
|
[54.048] I: Igniter turned off.
|
|
|
|
[54.048] I: Pausing for 3000ms
|
2022-12-22 02:07:46 +00:00
|
|
|
A shutdown has already been initiated and the blower is preventing shutdown.
|
2023-01-03 22:01:23 +00:00
|
|
|
[57.05] I: Pausing for 3000ms
|
|
|
|
[60.052] I: Blower can be turned off.
|
2022-12-22 02:07:46 +00:00
|
|
|
Shutting down...
|
2023-01-03 22:01:23 +00:00
|
|
|
[60.053] I: Pausing for 3000ms
|
|
|
|
Shutdown has been initiated.
|
|
|
|
[63.055] I: Pausing for 3000ms
|
|
|
|
[66.057] I: Blower can be turned off.
|
|
|
|
Shutting down...
|
|
|
|
[66.057] I: Pausing for 3000ms
|
|
|
|
Shutdown has been initiated.
|
|
|
|
[69.059] I: Pausing for 3000ms
|
|
|
|
[72.06] I: Blower can be turned off.
|
2022-12-22 02:07:46 +00:00
|
|
|
Shutting down...
|
2023-01-03 22:01:23 +00:00
|
|
|
[72.06] I: Pausing for 3000ms
|