# New Relay Layout
|
|||
|
|
|||
|
12VDC Power Supply
|
|||
|
|
|
|||
|
Exhaust--------SSR-40DA-|-----------------NC 3V Relay--------GPIO
|
|||
|
|
|
|||
|
Igniter--------SSR-40DA-|-----------------NO 3V Relay--------GPIO
|
|||
|
|
|
|||
|
Auger----------SSR-40DA-|-----------------NO 3V Relay--------GPIO
|
|||
|
|
|
|||
|
GND
|
|||
|
|
|||
|
# Power Supply
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Flyback Diode (for DC coils)
|
|||
|
|
|||
|
Purpose: Protects other components from the inductive voltage spike generated when the relay’s coil is de-energized. This voltage spike can damage transistors or other switching components.
|
|||
|
Type: A simple 1N4007 diode or similar can be used.
|
|||
|
Placement: Connect the diode across the relay coil, with the cathode (striped side) to the positive voltage and the anode to the negative end of the coil.
|
|||
|
|
|||
|
Capacitor (for Noise Suppression)
|
|||
|
|
|||
|
Purpose: A capacitor can be added across the relay contacts to reduce arcing and noise caused by contact bounce, which can help reduce wear.
|
|||
|
Type: Use a ceramic or film capacitor, typically around 0.1 µF, rated for the expected voltage.
|
|||
|
Placement: Place the capacitor across the relay’s switching contacts. For high-voltage AC circuits, ensure the capacitor is rated accordingly (e.g., X2 type for AC line).
|